Darren Nix

Tip of the Month: System Testing 101

I was recently asked to review and test a large security management system. Upon scheduling the testing date, I was asked if a construction review and auditing agency could follow us during the testing. The agency’s primary objective was to review and audit design and construction projects on a very routine basis. During the testing, the representatives from the agency asked questions and took many notes. I quickly realized that this was a learning opportunity for them. I was somewhat shocked that this type of agency did not fully understand the elements of a security management system and how to test the system. Nevertheless, I was more than happy to instruct along the way.

Whether you are directly responsible for routine audits, similar to this agency; a security professional accountable for testing your company’s systems; or even a home owner with a burglar alarm system, you must fully understand how to test your system and conduct frequent, routine testing.

When testing a system, the main objective is to ensure all equipment is functioning properly and all devices are reporting correctly (e.g. door alarms, video cameras, etc.). There are certainly many methods of testing multiple types of devices, equipment and systems; however, here are some of the basics:

1. Contact alarm operators – Before you begin testing, you should contact those responsible for monitoring the alarm activity on the system. In some cases, that may be a third party company. If so, you should request for them to keep an activity log during your testing time.

2. Arm the system – When testing a burglar alarm system, you must first arm the system. If you are testing a security management system, you should make sure all alarm devices are set to report alarm conditions during the testing period.

3. Doors

a. Door status switch or alarm contact – If a magnetic switch is used, place a magnet in front of the switch for a few seconds while the door is open. When removed, the alarm should report.

b. If using a 'door held open' alarm on a security management system, leave the door open and do not place the magnet in front of the switch for the amount of time allowed in the system for a door to stay open before an alarm sounds.

4. Card Readers – Use a variety of credentials for testing. Each credential should be set for the following:

a. Access granted
b. Access denied
c. Unknown badge

5. Cameras – Check for the following: (some systems will initiate an alarm on some events)

a. Correct field-of-view
b. Focused
c. Recording at set times
d. Loss of video signal
e. Covered lens
f. Clean domes

Finally, make sure you test all of the systems communications and associated alarms and be thorough when testing all aspects of your system.

About the Author

Darren Nix is a senior associate at Risk Management Associates, Inc.

Featured

  • The Yellow Brick Road

    The road to and throughout Wednesday's and Thursday's ISC West was crowded but it was amazing. Read Now

    • Industry Events
    • ISC West
  • An Inside Look From Napco at ISC West

    Get a look into the excitement at ISC West 2025 from Napco. Hear from some of their top-tech executives live from the show floor. Read Now

    • Industry Events
    • ISC West
  • Upping the Ante

    I am not a betting man in terms of cards, dice, blackjack or that wheel with the black marble racing around the circumference of a spinning wheel, but I would bet on the success of ISC West this year. Read Now

    • Industry Events
    • ISC West
  • It's Show Time

    I am one of those people that likes to see things get bigger and better. As advertised, ISC West is going to be bigger (more exhibitors) and better (more attendees). It’s show time in Las Vegas. Read Now

    • Industry Events
    • ISC West
  • SIA Releases New Report on Operational Security Technology

    The Security Industry Association (SIA) has released an impactful new resource – Operational Security Technology: Principles, Challenges and Achieving Mission-Critical Outcomes Leveraging OST. Read Now

New Products

  • ComNet CNGE6FX2TX4PoE

    The ComNet cost-efficient CNGE6FX2TX4PoE is a six-port switch that offers four Gbps TX ports that support the IEEE802.3at standard and provide up to 30 watts of PoE to PDs. It also has a dedicated FX/TX combination port as well as a single FX SFP to act as an additional port or an uplink port, giving the user additional options in managing network traffic. The CNGE6FX2TX4PoE is designed for use in unconditioned environments and typically used in perimeter surveillance.

  • HD2055 Modular Barricade

    Delta Scientific’s electric HD2055 modular shallow foundation barricade is tested to ASTM M50/P1 with negative penetration from the vehicle upon impact. With a shallow foundation of only 24 inches, the HD2055 can be installed without worrying about buried power lines and other below grade obstructions. The modular make-up of the barrier also allows you to cover wider roadways by adding additional modules to the system. The HD2055 boasts an Emergency Fast Operation of 1.5 seconds giving the guard ample time to deploy under a high threat situation.

  • Camden CM-221 Series Switches

    Camden CM-221 Series Switches

    Camden Door Controls is pleased to announce that, in response to soaring customer demand, it has expanded its range of ValueWave™ no-touch switches to include a narrow (slimline) version with manual override. This override button is designed to provide additional assurance that the request to exit switch will open a door, even if the no-touch sensor fails to operate. This new slimline switch also features a heavy gauge stainless steel faceplate, a red/green illuminated light ring, and is IP65 rated, making it ideal for indoor or outdoor use as part of an automatic door or access control system. ValueWave™ no-touch switches are designed for easy installation and trouble-free service in high traffic applications. In addition to this narrow version, the CM-221 & CM-222 Series switches are available in a range of other models with single and double gang heavy-gauge stainless steel faceplates and include illuminated light rings.