Darren Nix

Tip of the Month: System Testing 101

I was recently asked to review and test a large security management system. Upon scheduling the testing date, I was asked if a construction review and auditing agency could follow us during the testing. The agency’s primary objective was to review and audit design and construction projects on a very routine basis. During the testing, the representatives from the agency asked questions and took many notes. I quickly realized that this was a learning opportunity for them. I was somewhat shocked that this type of agency did not fully understand the elements of a security management system and how to test the system. Nevertheless, I was more than happy to instruct along the way.

Whether you are directly responsible for routine audits, similar to this agency; a security professional accountable for testing your company’s systems; or even a home owner with a burglar alarm system, you must fully understand how to test your system and conduct frequent, routine testing.

When testing a system, the main objective is to ensure all equipment is functioning properly and all devices are reporting correctly (e.g. door alarms, video cameras, etc.). There are certainly many methods of testing multiple types of devices, equipment and systems; however, here are some of the basics:

1. Contact alarm operators – Before you begin testing, you should contact those responsible for monitoring the alarm activity on the system. In some cases, that may be a third party company. If so, you should request for them to keep an activity log during your testing time.

2. Arm the system – When testing a burglar alarm system, you must first arm the system. If you are testing a security management system, you should make sure all alarm devices are set to report alarm conditions during the testing period.

3. Doors

a. Door status switch or alarm contact – If a magnetic switch is used, place a magnet in front of the switch for a few seconds while the door is open. When removed, the alarm should report.

b. If using a 'door held open' alarm on a security management system, leave the door open and do not place the magnet in front of the switch for the amount of time allowed in the system for a door to stay open before an alarm sounds.

4. Card Readers – Use a variety of credentials for testing. Each credential should be set for the following:

a. Access granted
b. Access denied
c. Unknown badge

5. Cameras – Check for the following: (some systems will initiate an alarm on some events)

a. Correct field-of-view
b. Focused
c. Recording at set times
d. Loss of video signal
e. Covered lens
f. Clean domes

Finally, make sure you test all of the systems communications and associated alarms and be thorough when testing all aspects of your system.

About the Author

Darren Nix is a senior associate at Risk Management Associates, Inc.

Featured

  • Video Surveillance Trends to Watch

    With more organizations adding newer capabilities to their surveillance systems, it’s always important to remember the “basics” of system configuration and deployment, as well as the topline benefits of continually emerging technologies like AI and the cloud. Read Now

  • New Report Reveals Top Trends Transforming Access Controller Technology

    Mercury Security, a provider in access control hardware and open platform solutions, has published its Trends in Access Controllers Report, based on a survey of over 450 security professionals across North America and Europe. The findings highlight the controller’s vital role in a physical access control system (PACS), where the device not only enforces access policies but also connects with readers to verify user credentials—ranging from ID badges to biometrics and mobile identities. With 72% of respondents identifying the controller as a critical or important factor in PACS design, the report underscores how the choice of controller platform has become a strategic decision for today’s security leaders. Read Now

  • Overwhelming Majority of CISOs Anticipate Surge in Cyber Attacks Over the Next Three Years

    An overwhelming 98% of chief information security officers (CISOs) expect a surge in cyber attacks over the next three years as organizations face an increasingly complex and artificial intelligence (AI)-driven digital threat landscape. This is according to new research conducted among 300 CISOs, chief information officers (CIOs), and senior IT professionals by CSC1, the leading provider of enterprise-class domain and domain name system (DNS) security. Read Now

  • ASIS International Introduces New ANSI-Approved Investigations Standard

    • Guard Services
  • Cloud Security Alliance Brings AI-Assisted Auditing to Cloud Computing

    The Cloud Security Alliance (CSA), the world’s leading organization dedicated to defining standards, certifications, and best practices to help ensure a secure cloud computing environment, today introduced an innovative addition to its suite of Security, Trust, Assurance and Risk (STAR) Registry assessments with the launch of Valid-AI-ted, an AI-powered, automated validation system. The new tool provides an automated quality check of assurance information of STAR Level 1 self-assessments using state-of-the-art LLM technology. Read Now

New Products

  • PE80 Series

    PE80 Series by SARGENT / ED4000/PED5000 Series by Corbin Russwin

    ASSA ABLOY, a global leader in access solutions, has announced the launch of two next generation exit devices from long-standing leaders in the premium exit device market: the PE80 Series by SARGENT and the PED4000/PED5000 Series by Corbin Russwin. These new exit devices boast industry-first features that are specifically designed to provide enhanced safety, security and convenience, setting new standards for exit solutions. The SARGENT PE80 and Corbin Russwin PED4000/PED5000 Series exit devices are engineered to meet the ever-evolving needs of modern buildings. Featuring the high strength, security and durability that ASSA ABLOY is known for, the new exit devices deliver several innovative, industry-first features in addition to elegant design finishes for every opening.

  • FEP GameChanger

    FEP GameChanger

    Paige Datacom Solutions Introduces Important and Innovative Cabling Products GameChanger Cable, a proven and patented solution that significantly exceeds the reach of traditional category cable will now have a FEP/FEP construction.

  • Unified VMS

    AxxonSoft introduces version 2.0 of the Axxon One VMS. The new release features integrations with various physical security systems, making Axxon One a unified VMS. Other enhancements include new AI video analytics and intelligent search functions, hardened cybersecurity, usability and performance improvements, and expanded cloud capabilities