One of America's most costly natural disasters are wildland fires, and wildland-urban interface (WUI) fires rank among the worst of these. WUI is the threshold where wildfires consume not only the landscape, but also infrastructure. Once that threshold is crossed, flames can spread – well, like wildfire. In quick succession, when a racing fire crosses the WUI, houses first smolder, then burn, and finally fall like wooden dominoes. And it can happen very quickly, as we all know.

Half of all billion-dollar blazes are WUI fires, which can ignite as many as a dozen homes a minute. This type of fire is both a wall of flames and a wave of firebrands. Lofting onto shingles or floating into eaves, the firebrands smolder before setting their resting place ablaze. More intrusive firebrands drift through gable vents or down chimneys, torching the house from within and creating new firebrands.

Since 2008, the Department of Homeland Security (DHS)'s Science and Technology Directorate (S&T) has been funding experimental WUI fire research at the National Institute of Standards and Technology (NIST) to discover when, how, and how often embers start fires after they land.

"WUI fires rank among America's most costly catastrophes," says S&T Office of Standards Executive Bert Coursey. "These studies aren't about blowing smoke; they're science at its best."

Recent breakthroughs have overturned a number of existing myths about wildfires:

• 6 millimeter (1/4-inch) wire mesh, when used to cover outside vents, as required by code, keeps embers out. NIST found that mesh with 6mm holes actually allowed many embers to slip through and easily ignite building materials placed behind the vents. Safety was improved with 1mm mesh (1/25 inch). While firebrands smoldered and passed through the mesh, building materials placed behind the vents no longer ignited.

• Firebrands cool too quickly to ignite a ceramic-tile roof. In NIST's tests, firebrands actually blew under newly laid tiles, then scorched through the underlying insulating tar paper and ignited the sheathing material. The situation was worse with aging tiles, whose gaps often trap materials that increase the fire risk.

• Most WUI house fires are sparked by a single rogue firebrand. On the contrary, most house fires erupt from an insidious accumulation of glowing firebrands.

Initial attempts to model the effects of wildfires were hindered by the variability of key elements, including leaves in gutters, dry needles under roofs, and smoldering embers in wooden joints. To address these challenges, fire researchers needed a controlled way to study firebrand-ignited house blazes, using real roofs and real fire.

Working with international partners at Japan's Building Research Institute, NIST's Engineering Laboratory hatched the NIST Firebrand Generator. Referred to as "The Dragon," this 6-foot-tall, stainless-steel, fire-breathing stovepipe devours wood chips, releasing their remnants as smoldering firebrands. The NIST Firebrand Generator produces embers from evergreens, similar to the trees that set off California's Angora conflagration of 2007.

Thanks to S&T funding, “The Dragon” has been tested on a range of full-scale house parts, including gutters, siding, eaves, walls, vents, and roofs.

But before facing The Dragon, some advanced experiments are conducted using NIST's four-foot-tall Reduced-Scale Firebrand Generator, or “Baby Dragon.” These small-scale experiments allow faster testing of the impact of firebrands on various materials and at various rates.

Together, these small and large-scale findings will lay the scientific foundation for new standards that will lead to more ember-resistant materials, treatments, barriers, and designs.

The firebrand research has sparked interest from academics and policymakers to home insurers — so much so that the Insurance Institute for Business & Home Safety (IBHS) cloned the NIST Dragon to rain firebrands in its own testing facility.

Researchers at NIST in Maryland are developing standard test methods and refining them as new materials, designs, and construction techniques are evaluated. For homeowners at nature's doorstep, S&T/NIST's firebrand research holds material importance. With one eye on the environment and the other on the economy, people need assurances that flame-retardant materials and add-ons will protect them better while lowering their insurance premiums.

"For the first time, we can determine the vulnerabilities that cause homes to ignite from firebrand showers," says Sam Manzello, a mechanical engineer in the NIST lab's Fire Measurements Group and visiting researcher at Japan's Building Research Institute. "This allows us to develop cost-effective fire protection codes and standards based on science, not on mere guesswork as it was in the past."

Featured

  • Video Surveillance Trends to Watch

    With more organizations adding newer capabilities to their surveillance systems, it’s always important to remember the “basics” of system configuration and deployment, as well as the topline benefits of continually emerging technologies like AI and the cloud. Read Now

  • New Report Reveals Top Trends Transforming Access Controller Technology

    Mercury Security, a provider in access control hardware and open platform solutions, has published its Trends in Access Controllers Report, based on a survey of over 450 security professionals across North America and Europe. The findings highlight the controller’s vital role in a physical access control system (PACS), where the device not only enforces access policies but also connects with readers to verify user credentials—ranging from ID badges to biometrics and mobile identities. With 72% of respondents identifying the controller as a critical or important factor in PACS design, the report underscores how the choice of controller platform has become a strategic decision for today’s security leaders. Read Now

  • Overwhelming Majority of CISOs Anticipate Surge in Cyber Attacks Over the Next Three Years

    An overwhelming 98% of chief information security officers (CISOs) expect a surge in cyber attacks over the next three years as organizations face an increasingly complex and artificial intelligence (AI)-driven digital threat landscape. This is according to new research conducted among 300 CISOs, chief information officers (CIOs), and senior IT professionals by CSC1, the leading provider of enterprise-class domain and domain name system (DNS) security. Read Now

  • ASIS International Introduces New ANSI-Approved Investigations Standard

    • Guard Services
  • Cloud Security Alliance Brings AI-Assisted Auditing to Cloud Computing

    The Cloud Security Alliance (CSA), the world’s leading organization dedicated to defining standards, certifications, and best practices to help ensure a secure cloud computing environment, today introduced an innovative addition to its suite of Security, Trust, Assurance and Risk (STAR) Registry assessments with the launch of Valid-AI-ted, an AI-powered, automated validation system. The new tool provides an automated quality check of assurance information of STAR Level 1 self-assessments using state-of-the-art LLM technology. Read Now

New Products

  • Camden CM-221 Series Switches

    Camden CM-221 Series Switches

    Camden Door Controls is pleased to announce that, in response to soaring customer demand, it has expanded its range of ValueWave™ no-touch switches to include a narrow (slimline) version with manual override. This override button is designed to provide additional assurance that the request to exit switch will open a door, even if the no-touch sensor fails to operate. This new slimline switch also features a heavy gauge stainless steel faceplate, a red/green illuminated light ring, and is IP65 rated, making it ideal for indoor or outdoor use as part of an automatic door or access control system. ValueWave™ no-touch switches are designed for easy installation and trouble-free service in high traffic applications. In addition to this narrow version, the CM-221 & CM-222 Series switches are available in a range of other models with single and double gang heavy-gauge stainless steel faceplates and include illuminated light rings.

  • HD2055 Modular Barricade

    Delta Scientific’s electric HD2055 modular shallow foundation barricade is tested to ASTM M50/P1 with negative penetration from the vehicle upon impact. With a shallow foundation of only 24 inches, the HD2055 can be installed without worrying about buried power lines and other below grade obstructions. The modular make-up of the barrier also allows you to cover wider roadways by adding additional modules to the system. The HD2055 boasts an Emergency Fast Operation of 1.5 seconds giving the guard ample time to deploy under a high threat situation.

  • Compact IP Video Intercom

    Viking’s X-205 Series of intercoms provide HD IP video and two-way voice communication - all wrapped up in an attractive compact chassis.